Cable Attenuation:
≤0.4dB / km λ = 1310 nm or ≤0.3dB/ km λ = 1550 nm
Maximum Connector Insertion Loss
0.3 dB +0.4 dB/ km * L(km) @ 1310nm according to IEC 61300-3-4 Method B
Minimum Return Loss
50dB @ 1310nm according to IEC 61300-3-6
Mechanical Date
Minimum Fiber Bending Radius(IEC 60794-1-21-E11)
Static 10D
Dynamic 20D
Maximum Tensile Strength(IEC 60794-1-21-E1)
Long term 400N
Short term 1300N
Crush Resistance (IEC 60794-1-21-E3)
Long Term 300n/10cm
Short Term 1000n/10cm
Water Penetration (IEC 60794-1-22 f5b)
h=1m, 24h, p<3m
Specification:
Environmental Data
Operation temperature -40 °C to +70°C Storage temperature -40 °C to +75 °C Installation temperature -5 °C to +50 °C
COMPLIANCE
RoHS EU Directive 2015/863 LSZH IEC 61034-2 / IEC 60754-2
UV resistant IEC 60068-2-5 Sb1 500h
Flame retardancy IEC 60332-1-2 / IEC 60332-3-24 (CAT-C)
Packing
Exposed Fibers And Connector Protected With Tube
Fibres And Connectors Protection
-By Pair (2Fo)
-Or By Group Of 24Fo
From Connector End Tiil Heatshrink
Parameter:
PART NUMBER | "L" (METER) |
9204.0510 10 | -0/+0.2 |
9204.0515 15 | -0/+0.2 |
9204.0520 20 | -0/+0.2 |
9204.0525 25 | -0/+0.2 |
9204.0530 30 | -0/+0.2 |
9204.0535 35 | -0/+0.2 |
9204.0540 40 | -0/+0.2 |
9204.0545 45 | -0/+0.2 |
9204.0550 50 | -0/+0.2 |
9204.0560 60 | -0/+1 |
9204.0570 70 | -0/+1 |
9204.0580 80 | -0/+1 |
9204.0590 90 | -0/+1 |
9204.0500 100 | -0/+1 |
DOCUMENT CONTROL | ||||
VERSION | DATE | STATUS | CHANGE | AUTHOR |
1 | 16/12/2018 | DRAFT | Creation | Luhuaqing |
2 | 28/2/2019 | DRAFT | Add packing information | Luhuaqing |
All all tolerances | ||||
3 | 4/4/2019 | DRAFT | Protection for packing | DCO |
New part number | ||||
New specification format | ||||
3.1 | 11/4/2019 | DRAFT | Update ordering code and label | DCO |
Update | ||||
- label width | ||||
3.2 1/9/2019 FINAL | - connector alignment tolerance to 15mm | DCO | ||
Add | ||||
- marker width limit |