Application: Duct/ Aerial
Characterisics:
1.Excellent mechanical and temperature performance guaranteed by the accurate excess Fiber length
2.Critical protection to fibers
3.The following measures are taken to ensure the water blocking performance of the cable.
4.Single steel wire used as the central strength member
5.Special water-blocking filling compound in the loose tube.
6.100% cable core filling
Storage/Operating Temperature: -40℃ to + 70℃
Standards:
Comply with standard YD/T 901-2009 as well as IEC 60794-1
Technical Parameters
Cable Type (increased by 2fibers) |
Fiber Count |
Tubes+Fillers |
Cable Diameter mm |
Cable Weight kg/km |
Tensile Strength Long/Short Term N |
Crush Resistance Long/Short Term N/100mm |
Bending Radius Static/Dynamic mm |
GYTA /S2 ~ 30 |
2 ~ 30 |
5 |
9.5 |
80 |
600/1500 |
300/1000 |
10D/20D |
GYTA/S 32 ~ 36 |
32 ~ 36 |
6 |
9.7 |
97 |
600/1500 |
300/1000 |
10D/20D |
GYTA/S 38 ~60 |
38 ~60 |
5 |
10.5 |
109 |
600/1500 |
300/1000 |
10D/20D |
GYTA /S62 ~72 |
62 ~72 |
6 |
11.5 |
126 |
600/1500 |
300/1000 |
10D/20D |
GYTA /S74 ~96 |
74 ~96 |
8 |
13.2 |
153 |
600/1500 |
300/1000 |
10D/20D |
GYTA /S98 ~120 |
98 ~120 |
10 |
14.6 |
182 |
600/2000 |
300/1000 |
10D/20D |
GYTA /S122 ~ 144 |
122 ~ 144 |
12 |
16.5 |
221 |
600/2500 |
300/1000 |
10D/20D |
GYTA/S 146 ~ 216 |
146 ~ 288 |
18 |
16.5 |
221 |
600/2500 |
300/1000 |
10D/20D |