Cable Section Design
Application
- ✰ Long-distance backbone network
- ✰ Urban ring network
- ✰ Access Network, FTTX
- ✰ Relay between communication machine rooms
- ✰ Building cable in integrated wiring
Main Features
- 2 ~ 576 cores
- Steel wire/FRP as strength member.
- Must be double Jacketed, with at least one layer of armor.
- Good resistance to lateral pressure and softness
- Loose-tube twisted single sheath or central tube structure
- Loose sleeve material with good hydrolysis resistance and high strength;
- Compact structure,excellent waterproof performance, excellent mechanical performance and temperature performance
- Bunched or ribbon fiber
- SM (G.652D, G.655, G.657.A1, G.657.A2) and MM (OM1, OM2, OM3, OM4) are available;
- PE, LSZH outer jacket material optional
Standards
GYTY53 cable complies with Standard YD/T 901-2001as well as IEC 60794-1.
Optical Characteristics
|
G.655 |
50/125μm |
62.5/125μm |
||
Attenuation (+20℃) |
@850nm |
|
|
≤3.0 dB/km |
≤3.0 dB/km |
@1300nm |
|
|
≤1.0 dB/km |
≤1.0 dB/km |
|
@1310nm |
≤0.36 dB/km |
≤0.40 dB/km |
|
|
|
@1550nm |
≤0.22 dB/km |
≤0.23dB/km |
|
|
|
Bandwidth (Class A) |
@850nm |
|
|
≥500 MHz·km |
≥200 MHz·km |
@1300nm |
|
|
≥1000 MHz·km |
≥600 MHz·km |
|
Numerical Aperture |
|
|
0.200±0.015NA |
0.275±0.015NA |
|
Cable Cut-off Wavelength |
≤1260nm |
≤1480nm |
|
|
Cable Technical Parameters
Cable Type |
Fiber Count |
Tubes |
Fillers |
Cable Diameter mm |
Cable Weight kg/km |
Tensile Strength Long/Short-Term N |
Crush Resistance Long/Short Term N/100mm |
Bending Radius Static |
GYTY53-2~6 |
2~6 |
1 |
5 |
13.8 |
188 |
1000/3000 |
1000/3000 |
10D/20D |
GYTY53-8~12 |
8~12 |
2 |
4 |
13.8 |
188 |
1000/3000 |
1000/3000 |
10D/20D |
GYTY53-14~18 |
14~18 |
3 |
3 |
13.8 |
188 |
1000/3000 |
1000/3000 |
10D/20D |
GYTY53-20~24 |
20~24 |
4 |
2 |
13.8 |
188 |
1000/3000 |
1000/3000 |
10D/20D |
GYTY53-26~30 |
26~30 |
5 |
1 |
13.8 |
188 |
1000/3000 |
1000/3000 |
10D/20D |
GYTY53-32~36 |
32~36 |
6 |
0 |
13.8 |
188 |
1000/3000 |
1000/3000 |
10D/20D |
GYTY53-38~48 |
38~48 |
4 |
1 |
14.6 |
206 |
1000/3000 |
1000/3000 |
10D/20D |
GYTY53-50~60 |
50~60 |
5 |
0 |
14.6 |
206 |
1000/3000 |
1000/3000 |
10D/20D |
GYTY53-62~72 |
62~72 |
6 |
0 |
15.0 |
215 |
1000/3000 |
1000/3000 |
10D/20D |
GYTY53-74~84 |
74~84 |
7 |
1 |
16.4 |
254 |
1000/3000 |
1000/3000 |
10D/20D |
GYTY53-86~96 |
86~96 |
8 |
0 |
16.4 |
254 |
1000/3000 |
1000/3000 |
10D/20D |
GYTY53-98~108 |
98~108 |
9 |
1 |
17.8 |
290 |
1000/3000 |
1000/3000 |
10D/20D |
GYTY53-110~120 |
110~120 |
10 |
0 |
17.8 |
290 |
1000/3000 |
1000/3000 |
10D/20D |
GYTY53-122~132 |
122~132 |
11 |
1 |
19.5 |
340 |
1000/3000 |
1000/3000 |
10D/20D |
GYTY53-134~144 |
134~144 |
12 |
0 |
19.5 |
340 |
1000/3000 |
1000/3000 |
10D/20D |
GYTY53-146~216 |
146~216 |
|
|
19.5 |
345 |
1000/3000 |
1000/3000 |
10D/20D |
Storage/Operating Temperature : -40℃ to + 70℃
Note: The structure’s size and specifications can be designed according to customer requirements. Contact us and send an inquiry to get the best offer and free samples now!