Cable Section Design
Application
- ✰ Long-distance backbone network
- ✰ Urban ring network
- ✰ Access Network, FTTX
- ✰ Relay between communication machine rooms
- ✰ Building cable in integrated wiring
Main Feature
1. The following measures are taken to ensure the water blocking performance of the cable.
2. Single steel wire used as the central strength member.
3. Special water-blocking filling compound in the loose tube.
4. 100% cable core filling.
Standards
Comply with standard YD/T 901-2009 as well as IEC 60794-1
Optical Characteristics
|
G.655 |
50/125μm |
62.5/125μm |
||
Attenuation (+20℃) |
@850nm |
|
|
≤3.0 dB/km |
≤3.0 dB/km |
@1300nm |
|
|
≤1.0 dB/km |
≤1.0 dB/km |
|
@1310nm |
≤0.36 dB/km |
≤0.40 dB/km |
|
|
|
@1550nm |
≤0.22 dB/km |
≤0.23dB/km |
|
|
|
Bandwidth (Class A) |
@850nm |
|
|
≥500 MHz·km |
≥200 MHz·km |
@1300nm |
|
|
≥1000 MHz·km |
≥600 MHz·km |
|
Numerical Aperture |
|
|
0.200±0.015NA |
0.275±0.015NA |
|
Cable Cut-off Wavelength |
≤1260nm |
≤1480nm |
|
|
GYTA Cable Technical Parameters
Cable Type |
Fiber Count |
Tubes |
Fillers |
Cable Diameter mm |
Cable Weight kg/km |
Tensile Strength Long/Short Term N |
Crush Resistance Long/Short Term N/100mm |
Bending Radius Static/Dynamic mm |
GYTA-2~6 |
2~6 |
1 |
4 |
9.7 |
90 |
600/1500 |
300/1000 |
10D/20D |
GYTA-8~12 |
8~12 |
2 |
3 |
9.7 |
90 |
600/1500 |
300/1000 |
10D/20D |
GYTA-14~18 |
14~18 |
3 |
2 |
9.7 |
90 |
600/1500 |
300/1000 |
10D/20D |
GYTA-20~24 |
20~24 |
4 |
1 |
9.7 |
90 |
600/1500 |
300/1000 |
10D/20D |
GYTA-26~30 |
26~30 |
5 |
0 |
9.7 |
90 |
600/1500 |
300/1000 |
10D/20D |
GYTA-32~36 |
32~36 |
6 |
0 |
10.2 |
104 |
1000/3000 |
300/1000 |
10D/20D |
GYTA-38~48 |
38~48 |
4 |
1 |
11.0 |
117 |
1000/3000 |
300/1000 |
10D/20D |
GYTA-50~60 |
50~60 |
5 |
0 |
11.0 |
117 |
1000/3000 |
300/1000 |
10D/20D |
GYTA-62~72 |
62~72 |
6 |
0 |
11.5 |
126 |
1000/3000 |
300/1000 |
10D/20D |
GYTA-74~84 |
74~84 |
7 |
1 |
13.4 |
154 |
1000/3000 |
300/1000 |
10D/20D |
GYTA-86~96 |
86~96 |
8 |
0 |
13.4 |
154 |
1000/3000 |
300/1000 |
10D/20D |
GYTA-98~108 |
98~108 |
9 |
1 |
14.8 |
185 |
1000/3000 |
300/1000 |
10D/20D |
GYTA-110~120 |
110~120 |
10 |
0 |
14.8 |
185 |
1000/3000 |
300/1000 |
10D/20D |
GYTA-122~132 |
122~132 |
11 |
1 |
16.9 |
228 |
1000/3000 |
300/1000 |
10D/20D |
GYTA-134~144 |
134~144 |
12 |
0 |
16.9 |
228 |
1000/3000 |
300/1000 |
10D/20D |
GYTA-146~216 |
146~216 |
|
|
16.9 |
233 |
1000/3000 |
300/1000 |
10D/20D |
Environmental Characteristics
- Transport/storage temperature: -40℃ to +70℃
- Compound flow: No filling compound or coating compound drop out of optical cable at 70℃
- Water penetration: No water comes out within 24 hours after 1m water head is applied to the entire cross section of 3m long optical cable
Hot Model Series Direct-buried Fiber optic cables
Duct optic fiber cables, also known as conduit or underground optic fiber cables, are designed for installation within protective ducts or conduits, typically buried underground. Duct fiber optic cables are a key infrastructure component in modern telecommunications, offering secure and reliable pathways for fiber optics within a protected environment. Their design caters to the needs of dense urban areas and is optimized for long-term performance with minimal maintenance.
Types of direct buried optic fiber cable:
GYTA Cable
Stranded Loose Tube Non-armored Cable
GYTS Cable
Stranded Loose Tube Light-armored Cable
GYFTA Cable
Non-armored Duct Fiber Optic Cable
GYFTY Cable
Non-armored Duct Fiber Optic Cable
GYXTW Cable
Light-armored Duct Fiber Optic Cable