Structure Design:
Fiber Type: G652D; G655C; 657A1; 50/125; 62.5/125; OM3; OM4 As Options
Application
- Self-support Aerial installation
- For installations next to high/low voltage electrical networks.
Protection
☑️ Water Block
☑️ Crush Resistance
☑️ Uv Resistant
Main Features:
1.Can be installed without shutting off the power
2.Light weight and small diameter reducing the load caused by ice and wind and the load on towers and backbone
3.Large span lengths and the largest span is over 1000m
4.Good performance of tensile strength and temperature
5.The design life expectance is 25-30 years
Standards:
GL Technology's ADSS Cables complies with IEC 60794-4、 IEC 60793、TIA/EIA 598 A.
Characteristics:
Parameters | Specification | |
Optical Characteristics | ||
Fiber Type | G652.D | |
Mode Field Diameter (um) | 1310nm | 9.1 ± 0.5 |
1550nm | 10.3 ± 0.7 | |
Attenuation Coefficient (dB/km) | 1310nm | ≤ 0.35 |
1550nm | ≤ 0.21 | |
Attenuation Non-uniformity (dB) | ≤ 0.05 | |
Zero Dispersion Wavelength ( λ0) (nm) | 1300 ~ 1324 | |
Max Zero Dispersion Slope (S0max) (ps/(nm2·km)) | ≤ 0.093 | |
Polarization Mode Dispersion Coefficient (PMDQ) (ps/km1/2) | ≤ 0.2 | |
Cut-off Wavelength (λcc) (nm) | ≤ 1260 | |
Dispersion Coefficient (ps/ (nm·km)) | 1288~1339nm | ≤ 3.5 |
1550nm | ≤ 18 | |
Effective Group Index of Refraction (Neff) | 1310nm | 1.466 |
1550nm | 1.467 | |
Geometric characteristic | ||
Cladding Diameter (um) | 125.0 ± 1.0 | |
Cladding Non-circularity (%) | ≤ 1.0 | |
Coating Diameter (um) | 245.0 ± 10.0 | |
Coating-cladding Concentricity Error (um) | ≤ 12.0 | |
Coating Non-circularity (%) | ≤ 6.0 | |
Core-cladding Concentricity Error (um) | ≤ 0.8 | |
Mechanical characteristic | ||
Curling (m) | ≥ 4 | |
Proof Stress (GPa) | ≥ 0.69 | |
Coating Strip Force (N) | Average Value | 1.0 5.0 |
Peak Value | 1.3 ~ 8.9 | |
Macro Bending Loss (dB) | Ф60mm, 100 Circles, @ 1550nm | ≤ 0.05 |
Ф32mm, 1 Circle, @ 1550nm | ≤ 0.05 |
Specifications:
Part code | ADSS-DJ-400-96F | |
Number of Fibers | Unit | 96Core |
Number of fiber in tube | Nos | 12 |
Number of loose tube | Nos | 8 |
Central strength member | Material | FRP |
Loose tube | Material | PBT |
peripheral strength member | Material | Aramid yarn |
Water block | Material | Water swellable tape and water block yarn |
Inner sheath | Material | PE |
Outer sheath | Material | HDPE |
Cable nominal Diameter | MM ±0.2 | 12.6 |
Cable nominal weight | Kg/Km ±5 | 109 |
Max allowable tension Load | N | 6900 |
Span | 400m span | |
Max. crush resistance | N | 2000 (Short term) / 1000 (Long term) |
Min. bending radius | At full load 20 x Cable OD (including poles) | |
At no load 15 x Cable OD | ||
Temperature range | Installation -0 -> +50 Operation -10 -> +70 |
ADSS Optical Cable Related Accessories:
Packing and Marking:
1. Packing
1.1 Each single length of cable shall be reeled on Wooden Drum suitable for long distance shipment.
1.2 Covered by plastic buffer sheet.
1.3 Sealed by strong wooden battens.
1.4 At least 1 m of inside end of cable will be reserved for testing.
1.5 Drum length
1.5.1 Standard drum length is 2000-4000m
1.5.2 Single length not less than 96% of standard length per drum shall be permitted for quantity not exceeding 10% of the total supply;
1.5.3 Total quantity is at least the ordered quantity.
2. Drum Marking
2.1 Cable drum
- Manufacturer brand;
- Roll-direction arrow;
- Cable outer end position indicating arrow;
- The word “FIBER OPTICAL Cable”;
- Origin, The word “MADE IN CHINA”;
- Caution plate indicating the correct method for loading, unloading and convey the cable;
- Other customer information such as contract no., project no., and delivery destination. (if needed)
2.2 Marking plate
- Product name;
- Cable type and size;
- Drum length;
- Gross / Net weight in kilograms;
- Drum number in meters;
- Manufacturer's name;
- Manufacturing year and month;
- Project number, contract number or purchasing order number (if needed).