Structure Design
Fiber Type
G652D; G655C; 657A1; 50/125; 62.5/125; OM3; OM4 As Options
Application
- Self-support Aerial installation
- For installations next to high/low voltage electrical networks.
Protection
☑️ Water Block
☑️ Crush Resistance
☑️ Uv Resistant
Main Features
- Uninterruptible power supply erection
- Adopt PE/AT sheath, excellent resistance to erosion
- Small cable diameter and lightweight help reduce the impact of ice, wind, and load on towers
- Large span, maximum span ≥ 1000 meters
- Great tensile strength and high/low temperature resistance
- Service life is expected over 30 years
Standards
GL Technology's ADSS Cables complies with IEEE 1222, IEC 60794-4-20, ANSI/ICEA S-87-640, TELCORDIA GR-20, IEC 60793-1-22, IEC 60794-1-2, IEC 60794.
Characteristics
Parameters | Specification | |
Optical Characteristics | ||
Fiber Type | G652.D | |
Mode Field Diameter (um) | 1310nm | 9.1 ± 0.5 |
1550nm | 10.3 ± 0.7 | |
Attenuation Coefficient (dB/km) | 1310nm | ≤ 0.35 |
1550nm | ≤ 0.21 | |
Attenuation Non-uniformity (dB) | ≤ 0.05 | |
Zero Dispersion Wavelength ( λ0) (nm) | 1300 ~ 1324 | |
Max Zero Dispersion Slope (S0max) (ps/(nm2·km)) | ≤ 0.093 | |
Polarization Mode Dispersion Coefficient (PMDQ) (ps/km1/2) | ≤ 0.2 | |
Cut-off Wavelength (λcc) (nm) | ≤ 1260 | |
Dispersion Coefficient (ps/ (nm·km)) | 1288~1339nm | ≤ 3.5 |
1550nm | ≤ 18 | |
Effective Group Index of Refraction (Neff) | 1310nm | 1.466 |
1550nm | 1.467 | |
Geometric characteristic | ||
Cladding Diameter (um) | 125.0 ± 1.0 | |
Cladding Non-circularity (%) | ≤ 1.0 | |
Coating Diameter (um) | 245.0 ± 10.0 | |
Coating-cladding Concentricity Error (um) | ≤ 12.0 | |
Coating Non-circularity (%) | ≤ 6.0 | |
Core-cladding Concentricity Error (um) | ≤ 0.8 | |
Mechanical characteristic | ||
Curling (m) | ≥ 4 | |
Proof Stress (GPa) | ≥ 0.69 | |
Coating Strip Force (N) | Average Value | 1.0 5.0 |
Peak Value | 1.3 ~ 8.9 | |
Macro Bending Loss (dB) | Ф60mm, 100 Circles, @ 1550nm | ≤ 0.05 |
Ф32mm, 1 Circle, @ 1550nm | ≤ 0.05 |
Specifications
Cable Design (ADSS-DJ-600M-24F) |
|
Central Element |
FRP |
Central Element Diameter |
2.5mm |
Fiber Count |
24 |
Fiber Coloring |
Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Rose, Aqua |
Fibers per Tube |
6 |
Number of Tube Positions |
6 |
Number of Active Tubes |
4 |
Buffer Tube Color Coding, Layer 1 |
Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow |
Buffer Tube Diameter |
2.5mm |
Tape |
Water-swellable |
Tensile Strength Elements |
Aramiad yarn 8050D X8 |
Number of Ripcords |
Yes |
Inner sheath Thickness |
1.0mm |
Outer Jacket Material |
High Density Polyethylene |
Outer Jacket Color |
Black |
Outer Jacket Nominal Thickness |
1.8mm |
Nominal Outer Diameter |
14.6mm |
Weight |
154kg/km |
Delivery Length |
4000m |
Max install load tension |
12500N 600m span |
ADSS Optical Cable-Related Accessories
Packing and Marking
1. Packing
1.1 Each single length of cable shall be reeled on Wooden Drum suitable for long distance shipment.
1.2 Covered by plastic buffer sheet.
1.3 Sealed by strong wooden battens.
1.4 At least 1 m of inside end of cable will be reserved for testing.
1.5 Drum length
1.5.1 Standard drum length is 2000-4000m
1.5.2 Single length not less than 96% of standard length per drum shall be permitted for quantity not exceeding 10% of the total supply;
1.5.3 Total quantity is at least the ordered quantity.
2. Drum Marking
2.1 Cable drum
- Manufacturer brand;
- Roll-direction arrow;
- Cable outer end position indicating arrow;
- The word “FIBER OPTICAL Cable”;
- Origin, The word “MADE IN CHINA”;
- Caution plate indicating the correct method for loading, unloading and convey the cable;
- Other customer information such as contract no., project no., and delivery destination. (if needed)
2.2 Marking plate
- Product name;
- Cable type and size;
- Drum length;
- Gross / Net weight in kilograms;
- Drum number in meters;
- Manufacturer's name;
- Manufacturing year and month;